Selco Reverse Power Relay T2000 | |
• Reverse Power Protection |
|
Download Data Sheets (.PDF) T2000 Data Sheet |
The T2000 Reverse Power Relay will protect the generator from being run as an electric motor. The T2000 will protect the prime mover of the generator against physical damage, but will also protect the parallel running generators from overload caused by the inversed load shift in a reverse power situation. |
|
|
Selco Excitation Lossr Relay T2100 | |
• Protects against excitation loss |
|
Download Data Sheets (.PDF) T2100 Data Sheet |
The T2100 Excitation Loss Relay protects against partial or complete excitation loss (field loss) on the synchronous generator. If the generator under parallel operation has a low excitation, a high inductive current is running into the generator. This current is detected and the breaker of the faulty generator is tripped, thus avoiding overload on the other generators with a possible black-out of the system. |
|
|
Selco Overcurrent Relay T2200 | |
• Protection of generators against overcurrent |
|
Download Data Sheets (.PDF) T2200 Data Sheet |
The SELCO T2200 has a broad application where all 3 phases or any single phase current detection will function for protection, control or monitoring. The relay detects the highest of the 3 input currents and, on exceeding the preset value, an output relay will be activated after a preset time delay. |
|
|
Selco Short Circuit Relay T2300 | |
• Protection of generators against short circuit |
|
Download Data Sheets (.PDF) T2300 Data Sheet |
The SELCO T2300 is intended for protection of generators, power transmissions and consumers against damage caused through short circuit by tripping the circuit breaker. The relay detects the highest of the 3 input currents and on exceeding the preset values, an output relay will be activated after a preset time delay or momentarily (0.1 second). |
|
|
Selco Dual Overcurrent Relay T2400 | |
• Protection of generators against overcurrent |
|
Download Data Sheets (.PDF) T2400 Data Sheet |
The SELCO T2400 consists of two combined over current relays, intended for protection, or monitoring of generators, power transmissions and consumer supply. |
|
|
Selco Overcurrent and Short Circuit Relay T2500 | |
• Over-Current Protection |
|
Download Data Sheets (.PDF) T2500 Data Sheet |
The SELCO T2500 is a high quality Over-Current and Short-Circuit relay intended for protection against thermal damage and faults caused by excessive currents. |
|
|
Selco Dual Current Relay T2600 | |
• Price competitive due to the combined functions |
|
Download Data Sheets (.PDF) T2600 Data Sheet |
The SELCO T2600 determines load depending start and stop level of the diesel generator. When load increases on the running diesel generators more than e.g. 90% adjustable, for a preset time, a start signal to call for the standby diesel generator will be provided. If the load decreases more than e.g. 45% adjustable, for a preset time, a stop signal will be provided to dismiss one of the diesel generators. |
|
|
Selco Overload Relay T2700 | |
• Overload Protection |
|
Download Data Sheets (.PDF) T2700 Data Sheet |
The T2700 Overload Relay will protect the generator from excessive active load. The T2700 is necessary to protect the prime mover and alternator against physical damage. |
|
|
Selco Overcurrent or Earth Fault Relay T2800 | |
• Protection of generators against earth faults or overcurrent |
|
Download Data Sheets (.PDF) T2800 Data Sheet |
The SELCO T2800 has a broad application as an earth fault - or single phase over current detection relay, it has a wide setting range for protection, control or monitoring. The relay detects the magnitude of the current and, on exceeding the preset value, an output relay will be activated after a preset time delay. |
|
|
Selco Differential Current Relay T2900 | |
• Protection of generators against differential currents |
|
Download Data Sheets (.PDF) T2800 Data Sheet |
|
|
|
Selco Frequency Relay T3000 | |
• Price competitive due to combined functions |
|
Download Data Sheets (.PDF) T3000 Data Sheet |
The SELCO T3000 is intended for effective frequency surveillance on generators, busbar or other distribution systems. The relay contains the functions "under frequency" and "over frequency" time delayed, and 2 individual output relays, one relay for each function. |
|
|
Selco Voltage Relay T3100 | |
• Price competitive due to combined functions |
|
Download Data Sheets (.PDF) T3100 Data Sheet |
The SELCO T3100 is intended for effective voltage surveillance on generators, busbar or other distribution systems. The relay contains the functions "under voltage" and "over voltage" time delayed, and 2 individual output relays, one relay for each function. |
|
|
Selco Insulation Monitoring Relay T3200 | |
• Price competitive due to combined functions • Visual indication of power, pick-up and relay tripping on both relays • High precision digital countdown timer for delayed output • Cost effective and highly reliable compact design |
|
Download Data Sheets (.PDF) T3200 Data Sheet |
The SELCO T3200 is intended for continuous insulation monitoring on three phase insulated networks on board ships. The relay monitors continuously two systems galvanically separated from each other, e.g. the busbar and the lighting system, or two busbar systems. |
|
|
Selco Voltage Relay 3 Phase T3300 | |
• 3 phase measurements |
|
Download Data Sheets (.PDF) T3300 Data Sheet |
The SELCO T3300 is intended for three phase effective voltage surveillance on generators, busbar or other distribution systems. The relay contains the functions "under voltage" and "over voltage" time delayed, and 2 individual output relays, one relay for each function. |
|
|
Selco Frequency Deviation Relay T3500 | |
• Acts on df/dt |
|
Download Data Sheets (.PDF) T3500 Data Sheet |
The SELCO T3500 Frequency Deviation Relay will, based on a simple AC voltage measurement, monitor the change in frequency over a time period of one second. |
|
|
Selco Auto Synchronizer for Electronic Speed Controllers T4000 | |
• Automatic synchronisation |
|
Download Data Sheets (.PDF) T4000 Data Sheet |
|
Download Manual (.PDF) T4000 Manual |
The SELCO T4000 Auto-Synchroniser provides automatic synchronisation and connection of a generator to a live bus bar. |
|
Selco Load Sharer for Electronic Speed Controllers T4400 | |
• Active load sharing |
|
Download Data Sheets (.PDF) T4400 Data Sheet |
|
Download Manual (.PDF) T4400 Manual |
The SELCO T4400 Load Sharer is designed to control a generator operating in parallel with the grid, or a generator operating in parallel with other generators (which are also controlled by T4400 units). |
Selco Auto Synchronizer for Conventional Governors T4500 | |
• Automatic synchronisation |
|
Download Data Sheets (.PDF) T4500 Data Sheet |
The SELCO T4500 Auto-Synchroniser provides automatic synchronisation and connection of a generator to a live bus bar. |
|
|
Selco Load Sharer for Conventional Governors T4800 | |
• Active load sharing |
|
Download Data Sheets (.PDF) T4800 Data Sheet |
The SELCO T4800 Load Sharer is designed to control a generator operating in parallel with the grid, or a generator operating in parallel with other generators (which are also controlled by T4800 units). |
|
|
Selco VAr Load Sharer T4900 | |
• Reactive load sharing |
|
Download Data Sheets (.PDF) T4900 Data Sheet |
The SELCO T4900 VAr-Load Sharer is designed to control a generator operating in parallel with the grid, or a generator operating in parallel with other generators (which are also controlled by T4900 units). |
|
|
Selco Paralleling Relay T5000 | |
• Manual synchronisation |
|
Download Data Sheets (.PDF) T5000 Data Sheet |
The T5000 Paralleling Relay is in fact a check synchroniser. |
|
|
Selco Electronic Potentiometer T7900 | |
• Programmable incr/decr ramps |
|
Download Data Sheets (.PDF) T7900 Data Sheet |
|
Download Manuals (.PDF) T7900 Manual |
The T7900 Electronic Potentiometer is typically used as an interface between a unit that provides increase/decrease contacts signals and electronic speed governors or voltage regulators (AVR) controlled by analogue voltage or current signals. |
Selco Blackout Limiter T8400 | |
• Enables fast clearing of a blackout |
|
Download Data Sheets (.PDF) T8400 Data Sheet |
The SELCO Blackout Limiter T8400 enables fast clearing of a blackout. If a blackout occurs, the first generator to have more than 90 % voltage will make the generator breaker close. It is possible to monitor up to 4 generators with 1 unit and up to 8 generators with 2 units. |
|
|